RIGOL 2 Command System
2-136 DS2000E Programming Guide
:MEASure:VAMP
:MEASure:VAVG
:MEASure:VBASe
:MEASure:VMAX
:MEASure:VMIN
:MEASure:VPP
:MEASure:VRMS
:MEASure:PVRMs
:MEASure:VTOP
:MEASure:MARea
:MEASure:MPARea
:MEASure:SOURce
Syntax
:MEASure:SOURce <sour>
:MEASure:SOURce?
Description
Set or query the signal source of the current measurement parameter.
Parameter
Name Type Range Default
<sour> Discrete {CHANnel1|CHANnel2|MATH} CHANnel1
Explanation
This command sets the signal source of all the measurement parameters except delay and phase. The
delay and phase measurements require two signal sources which can be set by the
:MEASure:SETup:DSA
and
:MEASure:SETup:DSB, :MEASure:SETup:PSA and :MEASure:SETup:PSB commands respectively.
Return Format
The query returns CHAN1, CHAN2, or MATH.