2 Command System RIGOL
DS2000E Programming Guide
2-241
:TIMebase[:MAIN]:SCALe
Syntax
:TIMebase[:MAIN]:SCALe <scale_value>
:TIMebase[:MAIN]:SCALe?
Description
Set or query the main time base and the unit is s/div.
Parameter
Name Type Range Default
<scale_value> Real
The range is related to the horizontal time
base mode of the oscilloscope
[1]
.
Y-T mode: 2ns/div
[2]
to 1ks/div
Roll mode: 200ms/div to 1ks/div
1us/div
Note
[1]
: Refer to the :TIMebase:MODE command.
Note
[2]
: This value is different for different models. For DS2202E, it is 2ns/div. For DS2102E, it is 5ns/div.
Return Format
The query returns the main time base in scientific notation.