EasyManua.ls Logo

Rigol DS2000E Series - Measure:period

Rigol DS2000E Series
365 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RIGOL 2 Command System
2-168 DS2000E Programming Guide
:MEASure:PERiod
Syntax 1
:MEASure:PERiod <chan>
Description 1
Enable the period measurement function of the specified channel.
Syntax 2
:MEASure:PERiod? <chan>
Description 2
Enable the period measurement function of the specified channel and return the measurement result.
Parameter
Name Type Range Default
<chan> Discrete {CHANnel1|CHANnel2|MATH} --
Return Format
The query returns the period measurement result in scientific notation. When the measurement result is
invalid, the query returns 9.9e37.
Example
:MEASure:PERiod CHANnel1
:MEASure:PERiod? CHANnel1
You can use the following commands to enable the period measurement function of the specified channel
and the statistic function of the measurement results as well as query the statistic maximum value,
minimum value, current value, average value, and standard deviation of the period measurement results.
:MEASure:PERiod:SMAXimum
:MEASure:PERiod:SMINimum
:MEASure:PERiod:SCURrent
:MEASure:PERiod:SAVerage
:MEASure:PERiod:SDEViation

Table of Contents

Other manuals for Rigol DS2000E Series

Related product manuals