2 Command System RIGOL
DS2000E Programming Guide
2-249
:TRIGger:CAN (Option)
:TRIGger:CAN:BAUD
:TRIGger:CAN:BUSer
:TRIGger:CAN:SOURce
:TRIGger:CAN:STYPe
:TRIGger:CAN:WHEN
:TRIGger:CAN:SPOint
:TRIGger:CAN:FTYPe
:TRIGger:CAN:LEVel
:TRIGger:CAN:BAUD
Syntax
:TRIGger:CAN:BAUD <baud_rate>
:TRIGger:CAN:BAUD?
Description
Set or query the signal rate of CAN trigger. The unit is b/s.
Parameter
Name Type Range Default
<baud_rate> Discrete
{10000|20000|33300|50000|62500|83300|100000|
125000|250000|500000|800000|1000000|USER}
10000
Explanation
When USER is selected, you can use the
:TRIGger:CAN:BUSer command to set the signal rate.
Return Format
The query returns the signal rate of CAN trigger in integer or returns USER.