RIGOL 2 Command System
2-250 DS2000E Programming Guide
:TRIGger:CAN:BUSer
Syntax
:TRIGger:CAN:BUSer <user baud>
:TRIGger:CAN:BUSer?
Description
Set or query the user-defined signal rate of CAN trigger. The unit is b/s.
Parameter
Name Type Range Default
<user baud> Integer 10000 to 1000000 50000
Return Format
The query returns the user-defined signal rate of CAN trigger in integer.
:TRIGger:CAN:SOURce
Syntax
:TRIGger:CAN:SOURce <source>
:TRIGger:CAN:SOURce?
Description
Set or query the trigger source of CAN trigger.
Parameter
Name Type Range Default
<source> Discrete {CHANnel1|CHANnel2} CHANnel1
Return Format
The query returns CHAN1 or CHAN2.