2 Command System      RIGOL 
DS2000E Programming Guide   
:MEASure:VBASe:SMAXimum 
:MEASure:VBASe:SMINimum 
:MEASure:VBASe:SCURrent 
:MEASure:VBASe:SAVerage 
:MEASure:VBASe:SDEViation 
 
Syntax 1
 
:MEASure:VBASe:SMAXimum <chan> 
:MEASure:VBASe:SMINimum <chan> 
:MEASure:VBASe:SCURrent <chan> 
:MEASure:VBASe:SAVerage <chan> 
:MEASure:VBASe:SDEViation <chan> 
 
Description 1 
Enable the amplitude base value measurement function of the specified channel and the statistic function 
of the measurement results.
 
 
Syntax 2 
:MEASure:VAVG:SMAXimum? <chan> 
:MEASure:VAVG:SMINimum? <chan> 
:MEASure:VAVG:SCURrent? <chan> 
:MEASure:VAVG:SAVerage? <chan> 
:MEASure:VAVG:SDEViation? <chan> 
 
Description 2 
Query the statistic maximum value (SMAXimum), minimum value (SMINimum), current value (SCURrent), 
average value (SAVerage), or standard deviation (SDEViation) of the amplitude base value measurement 
results when the amplitude base value measurement function of the specified channel and the statistic 
function of the measurement results are enabled.
 
 
Parameter 
Name  Type  Range  Default 
<chan>  Discrete  {CHANnel1|CHANnel2|MATH}  -- 
 
Explanation 
The unit is determined by the unit selected for the signal source channel (refer to 
the 
:CHANnel<n>:UNITs command). 
 
Return Format 
The query returns the statistic maximum value, minimum value, current value, average value, or standard 
deviation of the amplitude base value measurement results in scientific notation. When the measurement 
results are invalid, the query returns 9.9e37.