EasyManuals Logo

Rigol DS2000E Series Programming Guide

Rigol DS2000E Series
365 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #274 background imageLoading...
Page #274 background image
RIGOL 2 Command System
2-258 DS2000E Programming Guide
:TRIGger:DURATion:TUPPer
Syntax
:TRIGger:DURATion:TUPPer <tupper>
:TRIGger:DURATion:TUPPer?
Description
Set or query the upper limit of the duration time of duration trigger. The unit is s.
Parameter
Name Type Range Default
<tupper> Real
When the trigger condition is LESS: 2ns to 4s
When the trigger condition is GLESs: 12ns to 4s
2us
Note: For the trigger condition of duration trigger, please refer to the :TRIGger:DURAtion:WHEN command.
Return Format
The query returns the upper limit of the duration time of duration trigger in scientific notation.

Table of Contents

Other manuals for Rigol DS2000E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DS2000E Series and is the answer not in the manual?

Rigol DS2000E Series Specifications

General IconGeneral
BrandRigol
ModelDS2000E Series
CategoryTest Equipment
LanguageEnglish

Related product manuals