RIGOL 2 Command System
2-258 DS2000E Programming Guide
:TRIGger:DURATion:TUPPer
Syntax
:TRIGger:DURATion:TUPPer <tupper>
:TRIGger:DURATion:TUPPer?
Description
Set or query the upper limit of the duration time of duration trigger. The unit is s.
Parameter
Name Type Range Default
<tupper> Real
When the trigger condition is LESS: 2ns to 4s
When the trigger condition is GLESs: 12ns to 4s
2us
Note: For the trigger condition of duration trigger, please refer to the :TRIGger:DURAtion:WHEN command.
Return Format
The query returns the upper limit of the duration time of duration trigger in scientific notation.