EasyManua.ls Logo

Rockwell Automation Allen-Bradley Kinetix 5500

Rockwell Automation Allen-Bradley Kinetix 5500
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
180 Rockwell Automation Publication 2198-UM001M-EN-P - November 2022
Appendix A Interconnect Diagrams
Power Wiring Examples You must supply input power components. The single-phase and three-phase
line filters are wired downstream of the circuit protection.
Single-axis Drive Wiring Examples
Figure 89 - Kinetix 5500 Drives Power Wiring (three-phase operation)
DATA +/EPWR+
DATA -/EPWR-
L3
L2
L1
24V_COM
+24V
2
1
MBRK -
MBRK +
DC+
DC-
D+
D-
IN1
COM
IN2
SHLD
1
2
4
3
2
1
1
2
3
4
MBRK -
MBRK +
U
V
W
2
1
4
3
2
1
DC+
SH
195…264V AC rms or
324…528V AC rms
Three-phase Input
Notes 1, 2
Bonded Cabinet Ground Bus *
Control Power
(CP) Connector
PE Ground
Note 6
Mains AC Input
(IPD) Connector
Circuit Protection *
Note 2
* Indicates User Supplied Component
2198-Hxxx-ERSx
Kinetix 5500 Drives
Chassis
Note 4
Ground Screws
Note 9
Customer
Supplied
+24V DC
Motor Brake
(BC) Connector
Three-phase
Motor Power
Connections
Note 11
Motor Power
(MP) Connector
Cable Shield
Clamp
Note 5
See table on page 179
for note information.
DC Bus
(DC) Connector
Note 7
Shunt
(RC) Connector
Motor Feedback
(MF) Connector
Digital Input
(IOD) Connector
Motor Brake
Connections
Motor Feedback
Connections
(refer to Figure 97
)
Registration and
Home Input
Connections
2198-DBxx-F
Three-phase
AC Line Filter
Note 3
Internal Shunt
Note 8

Table of Contents

Other manuals for Rockwell Automation Allen-Bradley Kinetix 5500

Related product manuals