Rockwell Automation Publication 2198-UM001M-EN-P - November 2022 33
Chapter 2 Plan the Kinetix 5500 Drive System Installation
Shared AC/DC and Hybrid Systems
Table 13 - Input Power UL Circuit-protection Specifications
Kinetix 5500 Drives Bussmann Fuse Cat. No. Molded Case CB Cat. No.
Drive Cat. No.
Drive Voltage
(three-
phase),
Nom
2 Axes 3 Axes 4 Axes
5
Axes
6
Axes
7 Axes
8
Axes
2 Axes 3 Axes 4 Axes
5
Axes
6
Axes
7 Axes 8 Axes
2198-H003-ERSx 240/480V KTK-R-10 KTK-R-15 140U-D6D3-C15 and 140UT-D7D3-C15
2198-H008-ERSx 240/480V KTK-R-15 KTK-R-20 140U-D6D3-C15 and 140UT-D7D3-C15
140U-D6D3-C20
and
140UT-D7D3-C20
2198-H015-ERSx 240/480V KTK-R-20 —
140U-D6D3-C15
and
140UT-D7D3-C15
140U-D6D3-C20
and
140UT-D7D3-
C20
—
2198-H025-ERSx 240/480V KTK-R-30 —
140U-D6D3-C20
and
140UT-D7D3-
C20
140U-D6D3-C30
and
140UT-D7D3-
C30
—
2198-H040-ERSx 240/480V KTK-R-30 LPJ-45SP LPJ-50SP —
140U-D6D3-C30
and
140UT-D7D3-
C30
140G-G6C3-C50 —
2198-H070-ERSx 240/480V LPJ-50SP — 140G-G6C3-C50 —
Table 14 - Input Power IEC (non-UL) Circuit-protection Specifications
Kinetix 5500 Drives DIN gG Fuses, Amps (max) Molded Case CB Cat. No.
Drives Cat. No.
Drive Voltage
(three-
phase),
Nom
2
Axes
3
Axes
4 Axes
5
Axes
6
Axes
7 Axes
8
Axes
2 Axes 3 Axes 4 Axes 5 Axes 6 Axes 7 Axes 8 Axes
2198-H003-ERSx
240/480V 10 16 140U-D6D3-C15 and 140UT-D7D3-C15
2198-H008-ERSx
240/480V 16 20 140U-D6D3-C15 and 140UT-D7D3-C15
140U-D6D3-C20
and
140UT-D7D3-
C20
2198-H015-ERSx
240/480V 20 –
140U-D6D3-C15
and
140UT-D7D3-C15
140U-D6D3-C20
and
140UT-D7D3-
C20
–
2198-H025-ERSx
240/480V 32 —
140U-D6D3-C20
and
140UT-D7D3-
C20
140U-D6D3-C30
and
140UT-D7D3-
C30
—
2198-H040-ERSx
240/480V 32 50 —
140U-D6D3-C30
and
140UT-D7D3-
C30
140G-G6C3-C50 —
2198-H070-ERSx
240/480V 50 — 140G-G6C3-C50 —