Serial Bus Analysis
R&S
®
RTB2000
214User Manual 1333.1611.02 ─ 04
"Bin"
String containing the binary pattern with a maximum of 64 bits. Char-
acters 0, 1 and X are allowed.
"Hex"
String containing the hexadecimal pattern with a maximum of 8 bytes.
Characters 0 to F and X are allowed.
Remote command:
TRIGger:A:LIN:DATA on page 421
12.6.4 LIN Decode Results
When the configuration of the serial bus is complete, the signal can be decoded:
1. In the "Bus" menu, enable "Decode".
2. In the "Display" menu, select the result display settings.
See Chapter 12.1.2, "Display Settings", on page 167.
3. In the "Bus Table" menu, enable the "Bus Table". Adjust the table settings.
See also: Chapter 12.1.3, "Bus Table: Decode Results", on page 167
The instrument captures and decodes the signal according to the protocol definition
and the configuration settings.
The color-coding of the various protocol sections and errors simplifies the interpretation
of the visual display. The decode information condenses or expands, depending on the
horizontal scale. Various data formats are available to show the result values.
Figure 12-28: Decoded LIN signal with bus table, trigger on frame start
LIN (Option R&S RTB-K3)

Table of Contents