Remote Control Commands
R&S
®
RTB2000
266User Manual 1333.1611.02 ─ 04
15.5 Trigger
General Trigger Settings.......................................................................................266
Edge Trigger......................................................................................................... 268
Width Trigger.........................................................................................................269
Video/TV Trigger...................................................................................................271
Pattern Trigger...................................................................................................... 272
Timeout Trigger.....................................................................................................275
15.5.1 General Trigger Settings
This section describes general trigger commands that are independent of the trigger
type.
TRIGger:A:MODE.......................................................................................................... 266
TRIGger:A:SOURce....................................................................................................... 266
TRIGger:A:TYPE........................................................................................................... 267
TRIGger:A:HOLDoff:MODE.............................................................................................267
TRIGger:A:HOLDoff:TIME...............................................................................................268
TRIGger:A:MODE <TriggerMode>
Sets the trigger mode. The trigger mode determines the behavior of the instrument if
no trigger occurs.
Parameters:
<TriggerMode> AUTO | NORMal
AUTO
The instrument triggers repeatedly after a time interval if the trig-
ger conditions are not fulfilled. If a real trigger occurs, it takes
precedence.
NORMal
The instrument acquires a waveform only if a trigger occurs.
*RST: AUTO
TRIGger:A:SOURce <Source>
Sets the trigger source for the selected A trigger type.
Trigger