DISPlay:STYLe <Style>
Defines how the waveform data is displayed
Parameters:
<Style> VECTors | DOTS
VECTors
Individual data points are connected by a line.
DOTS
Only the data points are displayed.
*RST: VECT
15.10.2 System Settings
CALibration................................................................................................................... 363
CALibration:STATe?.......................................................................................................363
SYSTem:NAME.............................................................................................................364
SYSTem:DATE..............................................................................................................364
SYSTem:TIME...............................................................................................................364
SYSTem:COMMunicate:INTerface[:SELect]..................................................................... 365
SYSTem:BEEPer:CONTrol:STATe.................................................................................. 365
SYSTem:BEEPer:ERRor:STATe..................................................................................... 365
SYSTem:BEEPer:TRIG:STATe....................................................................................... 365
SYSTem:BEEPer[:IMMediate].........................................................................................365
SYSTem:SET................................................................................................................ 365
SYSTem:ERRor[:NEXT]?................................................................................................365
SYSTem:ERRor:ALL?.................................................................................................... 366
SYSTem:PRESet...........................................................................................................366
SYSTem:EDUCation:PRESet..........................................................................................366
SYSTem:DFPRint?........................................................................................................ 366
SYSTem:TREE?............................................................................................................366
CALibration
Calibration starts the self-alignment process. It can take several minutes. Consider
your timeout settings.
Calibration? returns information on the state of the self-alignment. Return values ≠
0 indicate an error.
Same as *CAL?.
Return values:
<SelfAlignment> Numeric status indicator
CALibration:STATe?
Returns the overall state of the self-alignment.
General Instrument Setup

Table of Contents

Related product manuals