Waveform Analysis
R&S
®
RTB2000
72User Manual 1333.1611.02 ─ 04
You can analyze math waveforms in the same way as channel waveforms: use zoom,
perform automatic and cursor measurements, and save as reference waveform.
To configure math waveforms
1. To enable the math waveform, press the MATH key.
2. To define the math waveform:
a) Press the MATH key to open the "Math" menu.
b) Select the source (operands).
c) Select the mathematical operation.
See also: Chapter 6.2.1, "Math Waveform Settings", on page 72.
3. To adjust vertical scale and position, use the rotary knobs in the Vertical section of
the front panel. See: Chapter 4.2.1, "VERTICAL Controls", on page 38.
4. To autoscale the math waveform, use the short menu.
6.2.1 Math Waveform Settings
The "Math" menu provides functions to configure a calculated waveform.
To open the "Math" menu:
a)
Tap the menu icon in the lower right corner of the screen.
b) Scroll down. Select "Math".
State
Activates the mathematics function and displays the resulting math waveform.
Mathematics