Remote Control Commands
R&S
®
RTB2000
430User Manual 1333.1611.02 ─ 04
SEARch:PROTocol:LIN:DATA <Data>
Defines the data pattern. The pattern length is defined with SEARch:PROTocol:LIN:
DLENgth.
The command is relevant if SEARch:PROTocol:LIN:CONDition is set to IDData.
Parameters:
<Data> String containing binary pattern with max. 64 bit. Characters 0,
1, and X are allowed. Make sure to enter complete bytes.
15.12 Mixed Signal Option (Option R&S RTB-B1)
● Logic Channels..................................................................................................... 430
● Parallel Buses....................................................................................................... 436
15.12.1 Logic Channels
Two different sets of commands are described in this chapter:
●
LOGic<p>:xxx:xxx:
Refer to the logic pod 1 ("D7...D0") or logic pod 2 ("D8...D15"). The suffix <p>
selects the logic pod, range 1..2.
●
DIGital<m>:xxx:xxx:
Refer to a specific logic channel. The suffix <m> selects the logic channel, range
0..15.
● Logic Channels - Activity Display..........................................................................430
● Logic Analyzer Configuration................................................................................ 431
● Logic Channels - Waveform Data......................................................................... 434
15.12.1.1 Logic Channels - Activity Display
LOGic<p>:CURRent:STATe:MAXimum?
DIGital<m>:CURRent:STATe:MAXimum?
LOGic<p>:CURRent:STATe:MINimum?
DIGital<m>:CURRent:STATe:MINimum?
Both commands together return the current status of the indicated logic channel/pod
regardless of the trigger settings, and even without any acquisition.
xxx:CURR:STAT:MIN returns xxx:CURR:STAT:MAX returns Signal
0 0 Low
1 1 High
0 1 Toggle
Mixed Signal Option (Option R&S RTB-B1)