Remote Control Commands
R&S
®
RTB2000
429User Manual 1333.1611.02 ─ 04
SEARch:PROTocol:LIN:ICONdition <IdCondition>
Sets the comparison condition for the identifier: If the pattern contains at least one X
(don't care), you can trigger on values equal or not equal to the specified value. If the
pattern contains only 0 and 1, you can also trigger on a range greater than or lower
than the specified value.
The command is relevant if SEARch:PROTocol:LIN:CONDition is set to
IDENtifier, IDData or IDERror.
Parameters:
<IdCondition> EQUal | NEQual | GTHan | LTHan
*RST: EQU
SEARch:PROTocol:LIN:IDENtifier
<Identifier>
Defines the identifier pattern.
The command is relevant if SEARch:PROTocol:LIN:CONDition is set to
IDENtifier, IDData or IDERror.
Parameters:
<Identifier> String containing binary pattern. Characters 0, 1, and X are
allowed. Enter the 6 bit identifier without parity bits, not the pro-
tected identifier.
SEARch:PROTocol:LIN:DLENgth <DataLength>
Defines the length of the data pattern - the number of bytes in the pattern.
The command is relevant if SEARch:PROTocol:LIN:CONDition is set to IDData.
Parameters:
<DataLength> Range: 1 to 8
Increment: 1
*RST: 1
Default unit: Byte
SEARch:PROTocol:LIN:DCONdition <DataCondition>
Sets the comparison condition for data: If the pattern contains at least one X (don't
care), you can trigger on values equal or not equal to the specified value. If the pattern
contains only 0 and 1, you can also trigger on a range greater than or lower than the
specified value.
The command is relevant if SEARch:PROTocol:LIN:CONDition is set to IDData.
Parameters:
<DataCondition> EQUal | NEQual | GTHan | LTHan
*RST: EQU