Signal Generation (Option R&S RTB-B6)
R&S
®
RTB2000
231User Manual 1333.1611.02 ─ 04
Sweep
Opens a menu to configure the sweep.
See Chapter 14.1.2, "Sweep Settings", on page 231.
Modulation
Opens a menu to configure the modulation.
See Chapter 14.1.3, "Modulation Settings", on page 232.
Invert
Inverts the waveform at the offset level.
Load
Select the user load, the load of the DUT at its connection. You can select either a
"50Ω" or a "High-Z" (high input impedance) load.
Remote command:
WGENerator:OUTPut:LOAD on page 446
14.1.2 Sweep Settings
In the sweep mode, the R&S RTB2000 generates a signal whose frequency gradually
changes from the Sweep Settings to the Stop Frequency for a certain Sweep Time.
Sweep
Enables or disables the sweeping.
Remote command:
WGENerator:SWEep[:ENABle] on page 447
Start Frequency
Sets the start frequency of the sweep signal.
Remote command:
WGENerator:SWEep:FSTart on page 447
Stop Frequency
Sets the stop frequency of the sweep signal.
Remote command:
WGENerator:SWEep:FEND on page 447
Sweep Time
Sets the duration of the sweep.
Remote command:
WGENerator:SWEep:TIME on page 447
Sweep
Sets the type of the sweep, a linear or logarithmic change of the frequency.
Remote command:
WGENerator:SWEep:TYPE on page 447