Remote Control Commands
R&S
®
RTB2000
446User Manual 1333.1611.02 ─ 04
WGENerator:MODulation:FSK:RATE <Rate>
Sets the rate at which signal switches between the carrier frequency and the hopping
frequency.
Parameters:
<Rate>
WGENerator:MODulation:RAMP:POLarity <Polarity>
Sets the polarity for the ramp function for a modulation waveform.
Parameters:
<Polarity> POSitive | NEGative
WGENerator:NOISe:ABSolute
<AbsoluteNoise>
Sets the noise of the waveform in volts.
Parameters:
<AbsoluteNoise>
WGENerator:NOISe:RELative <RelativeNoise>
Sets the noise of the generated waveform in percentage of the amplitude.
Parameters:
<RelativeNoise>
WGENerator:OUTPut:DESTination <Destination>
Sets the output connector for the function generator waveform.
Parameters:
<Destination> BNC | P3
WGENerator:OUTPut:LOAD <Load>
Select the user load, the load of the DUT at its connection. You can select either a
"50Ω" or a "High-Z" (high input impedance) load.
Parameters:
<Load> HIGHz | R50
WGENerator:OUTPut[:ENABle] <OutputEnable>
Enables the function generator and outputs the waveform.
Parameters:
<OutputEnable> ON | OFF