Remote Control Commands
R&S
®
RTB2000
401User Manual 1333.1611.02 ─ 04
<o> *
Selects the word number.
Return values:
<StopTime> Range: depends on sample rate, record length, and time
base
Increment: depends on the time base
Default unit: s
Usage: Query only
BUS<b>:UART:RX:FRAMe<n>:WORD<o>:VALue?
BUS<b>:UART:TX:FRAMe<n>:WORD<o>:VALue?
Return the value of the specified symbol (word) on the Rx line and Tx line, respec-
tively.
Suffix:
<b>
.
1..2
Selects the bus.
Note: SPI/SSPI and UART protocols occupy two bus lines.
<n> *
Selects the frame.
<o> *
Selects the word number.
Return values:
<Value> Range: 0 to 511
Increment: 1
Usage: Query only
BUS<b>:UART:FRAMe<n>:WORD<o>:VALue?
BUS<b>:UART:FRAMe<n>:WORD<o>:RXValue?
BUS<b>:UART:FRAMe<n>:WORD<o>:TXValue?
Suffix:
<p>
.
1..2
<n> *
<o> *
Return values:
<TxValue>
Usage: Query only
15.11.5 CAN
CAN is the Controller Area Network, a bus system used within automotive network
architecture.
Serial Bus Analysis