Remote Control Commands
R&S
®
RTB2000
347User Manual 1333.1611.02 ─ 04
DIGital<m>:DATA:YORigin?............................................................................................348
REFCurve<m>:DATA:Yorigin?........................................................................................ 348
CHANnel<m>:DATA:YINCrement?.................................................................................. 348
CHANnel<m>:DATA:ENVelope:YINCrement?...................................................................348
CALCulate:QMATh:DATA:YINCrement?.......................................................................... 348
MASK:DATA:YINCrement?.............................................................................................348
LOGic<p>:DATA:YINCrement?....................................................................................... 348
DIGital<m>:DATA:YINCrement?......................................................................................348
REFCurve<m>:DATA:YINCrement?.................................................................................348
CHANnel<m>:DATA:YRESolution?..................................................................................349
CHANnel<m>:DATA:ENVelope:YRESolution?.................................................................. 349
CALCulate:QMATh:DATA:YRESolution?..........................................................................349
MASK:DATA:YRESolution?............................................................................................ 349
LOGic<p>:DATA:YRESolution?.......................................................................................349
DIGital<m>:DATA:YRESolution?..................................................................................... 349
REFCurve<m>:DATA:YRESolution?................................................................................349
CHANnel<m>:DATA:XORigin?
CHANnel<m>:DATA:ENVelope:XORigin?
CALCulate:QMATh:DATA:XORigin?
MASK:DATA:XORigin?
LOGic<p>:DATA:XORigin?
DIGital<m>:DATA:XORigin?
REFCurve<m>:DATA:Xorigin?
Return the time of the first sample of the indicated waveform.
The commands are relevant for data conversion if binary data format is defined
(FORM UINT, 8|16|32).
Suffix:
<m>
.
1..4
Return values:
<Xorigin> Time in s
Example: See Chapter 15.2.1.4, "Reading Waveform Data in Unsigned
Integer Format", on page 243
Usage: Query only
CHANnel<m>:DATA:XINCrement?
CHANnel<m>:DATA:ENVelope:XINCrement?
CALCulate:QMATh:DATA:XINCrement?
MASK:DATA:XINCrement?
LOGic<p>:DATA:XINCrement?
DIGital<m>:DATA:XINCrement?
REFCurve<m>:DATA:XINCrement?
Return the time difference between two adjacent samples of the indicated waveform.
The commands are relevant for data conversion if binary data format is defined
(FORM UINT, 8|16|32).