Remote Control
R&S
®
RTM20xx
327User Manual 1317.4726.02 ─ 01
CURSor<m>:AOFF
Switches the cursor off.
Suffix:
<m>
.
1
The numeric suffix is irrelevant.
Usage: Event
CURSor<m>:STATe <State>
Activates or deactivates the cursor measurement.
Suffix:
<m>
.
1
The numeric suffix is irrelevant.
Parameters:
<State> ON | OFF
*RST: OFF
CURSor<m>:SOURce <Source>
Defines the source of the cursor measurement.
Suffix:
<m>
.
1
The numeric suffix is irrelevant.
Command Reference