Display
R&S
®
RTM20xx
64User Manual 1317.4726.02 ─ 01
To configure the intensity of an XY-waveform modulated by a signal amplitude
Prerequisite: The "Display Mode" is set to "XY", and the XY-diagram is configured.
1. Press "DISPLAY > XYZ Setup > Z Setup".
2. Press the left "Source Z" softkey until "ON" is highlighted to activate intensity control
by the Z source.
3. Press the second "Source Z" softkey repeatedly until the required channel for inten-
sity control is selected.
4. Press "Z-Intensity" until "Modulation" is highlighted to select intensity control via
modulation.
To configure the intensity of an XY-waveform using a threshold value
Prerequisite: The "Display Mode" is set to "XY", and the XY-diagram is configured.
1. Press "DISPLAY > XYZ Setup > Z Setup".
2. Press the left "Source Z" softkey until "ON" is highlighted to activate intensity control
by the Z source.
3. Press the second "Source Z" softkey repeatedly until the required channel for inten-
sity control is selected.
4. Press "Z-Intensity" until "ON | OFF" is highlighted to select intensity control via a
threshold value.
5. Press "Threshold" and enter the required value to define the threshold value.
4.2.2 XYZ Setup Menu
The setup of XY-diagrams is a submenu of the "Display" menu.
Access: DISPLAY > "XYZ Setup"
Source X
Defines the source to be displayed in x direction in an XY-diagram, replacing the usual
time base. The source can be selected from any of the analog channels.
The function is available in R&S RTM1054.
Remote command:
DISPlay:XY:XSOurce on page 315
Source Y1
Defines the (first) source to be displayed in y direction in an XY-diagram. The source can
be selected from any of the analog channels.