EasyManua.ls Logo

Rohde & Schwarz RTM2032 - 6.3 Automatic Measurements; Automatic Measurements; Measurement Types and Results; Measurement Types

Rohde & Schwarz RTM2032
499 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Measurements
R&S
®
RTM20xx
87User Manual 1317.4726.02 ─ 01
Remote command:
MEASurement<m>:ALL[:STATe] on page 335
MEASurement<m>:AON on page 335
MEASurement<m>:AOFF on page 335
MEASurement<m>:ARESult? on page 335
6.3 Automatic Measurements
Using the MEAS key you can configure up to four amplitude and time measurements or
pulse counts on one of the active channel, reference or math waveforms.
If MSO option R&S RTM-B1 is installed, active digital channels are available as mea-
surement sources for time and count measurements.
Measurement Types and Results...........................................................................87
Configuring and Performing Automatic Measurements..........................................93
Auto Measure Menu (MEAS key)............................................................................94
6.3.1 Measurement Types and Results
Measurement Types...............................................................................................87
Measurement Results.............................................................................................92
Statistics..................................................................................................................93
6.3.1.1 Measurement Types
The R&S RTM provides a varity of automatic measurements:
Mean Value...................................................................................................................88
RMS Value....................................................................................................................88
Mean Cycle...................................................................................................................88
RMS Cycle....................................................................................................................88
Peak Peak.....................................................................................................................88
Peak +...........................................................................................................................88
Peak -............................................................................................................................88
Frequency.....................................................................................................................88
Period............................................................................................................................89
Amplitude......................................................................................................................89
Crest factor....................................................................................................................89
Top Level......................................................................................................................89
Base Level....................................................................................................................89
Pulse Width (positive pulse)..........................................................................................89
Pos. Overshoot.............................................................................................................89
Neg. Overshoot.............................................................................................................89
Pulse Width (negative pulse)........................................................................................90
Duty Cycle +..................................................................................................................90
Automatic Measurements

Table of Contents

Related product manuals