8 | Functions and settings
Page 40 of 104 CIRUS
®
UPT-6400 VERSION 1 | EN-US
Menu
num-
ber
Menu
item
Available
only
when the
timer is
activated
(menu
number
401)
Description Setting range
404 Begin-
ning of
sealing
time
x Specify here whether the sealing time (menu number
104) begins directly when the start signal is applied or not
until 95% of the setpoint is reached.
• When heater is
started
• When tempera-
ture is reached
405 Alarm re-
lay
How the alarm relay is switched can be configured here.
• Normal: In the event of an alarm, the alarm relay out-
put (terminals 12, 13, 14) functions as a make con-
tact.
• Inverse: In the event of an alarm, the alarm relay out-
put (terminals 12, 13, 14) functions as a break con-
tact.
This setting is also applied to relayK1, relayK2 and out-
put A1, if they are configured to Active for alarm
(menu numbers 408, 409 and410)
• Normal
• Inverse
406 Analog
output
supplies
Select which information should be provided at the actual
value output (terminals 17+18).
• Actual tempera-
ture
• 10V reference
• Regulation ratio
• OFF