8 | Functions and settings
Page 46 of 104 CIRUS
®
UPT-6400 VERSION 1 | EN-US
Menu
num-
ber
Menu
item
Available
only
when the
timer is
activated
(menu
number
401)
Description Setting range
510 Maxi-
mum di-
agnosis
tempera-
ture
Maximum diagnosis temperature (from one of the analog
sources, determined by menu number 508). If the tem-
perature exceeds the threshold, error code 828 appears.
Available only when diagnosis temperature is activated in
menu 508.
-99…999°C
Information menu
Menu
num-
ber
Menu
item
Available
only
when the
timer is
activated
(menu
number
401)
Description Setting range
601 Cycle
counter
The number of heating pulses is counted and displayed.
Touching Manual is counted only when Manual starts a
sealing cycle (menu number 206 in the Operation
menu).
Reset the counter by pressing Enter, Down and then
Enter again.
The total cycles as well as the operating hours of the
temperature counter are displayed. These values cannot
be reset.
602 Cycle
counter
(calibra-
tion
channel)
The number of pulses (not manual pulses) for each cali-
bration channel is counted and displayed.
Press Enter to select the counter. Reset the counter by
pressing Down and then Enter again.
603 Date
Time
The date and time are displayed.
To change the date or time, press Enter to select the
position to be changed. Press Up and Down to adjust the
selected value.
604 ID plate Shows the following information regarding the tempera-
ture controller:
• Device type
• Article number
• Serial number
• Firmware version
• Hardware version
• Modification
• Number of entries in error protocol
• Number of operating hours