Error and alarm messages
Diagnostics
Fatal error code F1611, error 108, subcode 036
Error message Faulty ELC range check.
Cause Faulty configuration data of the ELC function.
Remedy • Undo the changes in the ELC configuration or enter new values.
• Reload the configuration data. Next switch the DCS..B option off and on again.
• If the error still persists, consult SEW Service for the proper MOVISAFE
®
software
version.
Fatal error code F1613, error 108, subcode 037
Error message Faulty OLC range check.
Cause Faulty configuration data of the OLC function.
Remedy • Undo the changes in the OLC configuration or enter new values.
• Reload the configuration data. Next switch the DCS..B option off and on again.
• If the error still persists, consult SEW Service for the proper MOVISAFE
®
software
version.
Fatal error code F1615, error 108, subcode 038
Error message Faulty ZSC range check.
Cause Faulty configuration data of the ZSC function.
Remedy • Undo the changes in the ZSC configuration or enter new values.
• Reload the configuration data. Next switch the DCS..B option off and on again.
• If the error still persists, consult SEW Service for the proper MOVISAFE
®
software
version.
Fatal error code F1617, error 108, subcode 039
Error message Faulty MSC range check.
Cause Faulty configuration data of the MSC function.
Remedy • Undo the changes in the MSC configuration or enter new values.
• Reload the configuration data. Next switch the DCS..B option off and on again.
• If the error still persists, consult SEW Service for the proper MOVISAFE
®
software
version.