Manual – MOVIDRIVE® MDX61B Safety Module MOVISAFE® DCS..B Option
113
9
Error and alarm messages
Diagnostics
Fatal error code F1633, error 108, subcode 046
Error message Faulty encoder type range check.
Cause Incorrectly configured encoder type.
Remedy • Undo the changes in the encoder configuration or enter new values.
• Reload the configuration data. Next switch the DCS..B option off and on again.
• If the error still persists, consult SEW Service for the proper MOVISAFE
®
software
version.
Fatal error code F1635, error 108, subcode 047
Error message Faulty encoder scaling range check.
Cause Incorrectly configured encoder distance.
Remedy • Undo changes made to the encoder distance (measuring length, resolution or
max. speed) or enter new values.
• Reload the configuration data. Next switch the DCS..B option off and on again.
• If the error still persists, consult SEW Service for the proper MOVISAFE
®
software
version.
Fatal error code F1637, error 108, subcode 048
Error message Faulty encoder position range check.
Cause Incorrectly configured encoder distance.
Remedy • Undo changes made to the encoder distance (measuring length, resolution or
max. speed) or enter new values.
• Reload the configuration data. Next switch the DCS..B option off and on again.
• If the error still persists, consult SEW Service for the proper MOVISAFE
®
software
version.
Fatal error code F1639, error 108, subcode 049
Error message Faulty PDM range check.
Cause Faulty configuration data of the PDM function.
Remedy • Undo the changes in the PDM configuration or enter new values.
• Reload the configuration data. Next switch the DCS..B option off and on again.
• If the error still persists, consult SEW Service for the proper MOVISAFE
®
software
version.
Fatal error code F2001/2002, error 108, subcode 050/051
Error message Error during internal data transmission.
Remedy Replace the DCS..B option and send it together with error number to SEW Service for
further inspection.
Fatal error code F2003/2004, error 108, subcode 052/053
Error message Error during internal data transmission.
Remedy Replace the DCS..B option and send it together with error number to SEW Service for
further inspection.
Fatal error code F3001/3002, error 108, subcode 054/055
Error message Internal program error.
Remedy Replace the DCS..B option and send it together with error number to SEW Service for
further inspection.