- 116 -
When EIT or EI option is ordered:
(Fig. 11.1-3)
When OUT1 and OUT2 are a non-contact voltage output or direct current output,
OUT1 is not electrically insulated from OUT2.
Insulation resistance: 10 M min., at 500 V DC
Dielectric strength Between input terminal and power terminal: 1.5 kV AC for 1 minute
Between output terminal and power terminal: 1.5 kV AC for 1 minute
Between output terminal (P24) and power terminal: 500 VAC for 1 minute
24
2
3
2
2
2
1
2
0
19
18
17
16
15
14
13
12
9
8
7
6
POWER
SUPPLY
CPU
EV1
EV2
OUT2
2
0
19
P24
DI1
DI2
Electrically insulated
OUT1
TC
RTD
DC
(
I
nput
)
TA: When EIT option is ordered.
EV3: When EI option is ordered.
TA
or
EV3