EasyManuals Logo

SICK Lector 620 Online Help

SICK Lector 620
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #115 background imageLoading...
Page #115 background image
ONLINE HELP SOPAS Chapter 5
LECTOR®620
Parameters
8013778/Y269/2013-11-27 © SICK AG · Germany · All rights reserved · Subject to change without notice 115
5.9.2.1.1 Conditions for image storing
The Conditions for image storing parameter is used to select the condition on which images
are stored for diagnosis.
• G
OOD READ: Only images of a successful code reading are stored.
• N
O READ: Only images of an unsuccessful code reading are stored.
• A
LL: All recorded images are stored.
• C
ONDITION MATCH 1: The recorded images are only stored if the read code corresponds to
the matchcode from C
ONDITION MATCH 1.
• C
ONDITION MULTCODES1: The recorded images are only stored if the number of read codes
corresponds to the required number from C
ONDITION MULTCODES1.
• C
ONDITION TEACHIN1: The recorded images are only stored if condition Matchcode Teach-
in 1 is met.
• C
ONDITION TEACHIN2: The recorded images are only stored if condition Match-code Teach-
in 2 (Additional) is met.
5.9.2.1.2 Prioritizing image output over the trigger
The Prioritizing image output over the trigger parameter defines a processing sequence for
outputting images and accepting an object trigger. If this parameter is activated, the diagno-
stics images are transmitted in full before the device accepts and processes an object trig-
ger for the subsequent reading process. If this parameter is deactivated, a trigger signal is
processed by the device in any case and an unfinished image output is interrupted.
To set up the reading device, the priority of the image output can be used to determine what
the device detects within a reading gate. If this parameter is activated, you can check the
object trigger interval and length of the reading process. In applications where image output
is more important than continuous object/code detection, it is only recommended to priori-
tize the image output for normal operation in exceptional circumstances.
5.9.2.1.3 Image selection
You use the Image selection parameter to select the images to be stored for each reading
gate.
• L
AST GOOD READ / LAST IMAGE: If the code reading was successful, the last image on which
one or more codes were read is stored. If the code reading was not successful, the most
recently recorded image is stored. (Recommended for applications for which the code does
not move out of the reading gate during reading.)
• F
IRST IMAGE: The first recorded image is stored. (Recommended for applications for which
the code is in motion during reading and for which triggering takes place to the code, i.e. the
first image already contains a code.)
• I
MAGE SEQUENCE: All recorded images are stored as a sequence. (Recommended for appli-
cations for which the reading gate is opened by an object and the position of the code on
the object is not known exactly.) The recording of image sequences is used to check trigge-
ring and recording quality for moving objects. The images are numbered top left. If image
numbers are missing, not all recordings can be decoded and the settings (e.g. code set-
tings) must be modified accordingly.