Chapter 5 ONLINE HELP SOPAS
LECTOR®620
64 © SICK AG · Germany · All rights reserved · Subject to change without notice 8013778/Y269/2013-11-27
Parameters
5.7.11.2.3 Fixed length
The Fixed length parameter is used to define several fixed code lengths. Only codes with one
of these defined code lengths are read.
By defining certain permitted code lengths, you restrict the range of codes to be read.
This can lead to a reduction in the decoding time.
5.7.11.3 GS1/EAN 128
The control characters in the EAN 128 code format can be replaced with alternative, user-
specific characters under the GS1/EAN 128 group. Control characters in the EAN 128 code
format are used at the start of the code to identify the code format and within the code to
classify the data groups. The user-specific characters are entered via the keyboard or clip-
board as hexadecimal values.
5.7.11.3.1 FC1-Value within code
With the parameter FC1-Value within code an alternative character for the FC1-character
(control character at the beginning of the code) can be defined for the EAN 128 code.
Up to three characters can be defined. Enter data as a decimal character.
5.7.11.3.2 FC1-Value on first position
With the parameter FC1-Value on first position an alternative character for the FC1-charac-
ter (control character at the beginning of the code) can be defined for the EAN 128 code.
Up to three characters can be defined. Enter data as a decimal character.
5.7.12 GS1 DataBar
If the GS1 DataBar parameter is activated, decoding is activated for the DataBar 14,
DataBar Expanded and DataBar Limited active code types. This requires the Pharmacode
code type to be deactivated. The configuration tab for the corresponding code types can be
seen and opened in SOPAS ET.
As only activated code types are processed, you can increase the processing speed by
deactivating the code types that are not being used.
5.7.12.1 General
Reading processes such as the number of necessary multireads, regulations for dealing
with the start and stop characters, or check digit tests are configured under the General
group.

Table of Contents

Other manuals for SICK Lector 620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector 620 and is the answer not in the manual?

SICK Lector 620 Specifications

General IconGeneral
BrandSICK
ModelLector 620
CategoryCard Reader
LanguageEnglish