Chapter 5 ONLINE HELP SOPAS
LECTOR®620
44 © SICK AG · Germany · All rights reserved · Subject to change without notice 8013778/Y269/2013-11-27
Parameters
5.6.1.2 Fixed speed
The Fixed speed parameter is used to enter a constant value for the feed speed of the con-
veyer belt in m/sec.
This speed is automatically converted to time/distance.
5.6.1.3 System increment resolution
You use the System increment resolution parameter to define the conversion factor for the
increment signal.
The value corresponds to the distance covered per increment in mm. For the concrete cal-
culation of speeds and distances, the value must be adapted to the incremental encoder
used.
5.7 Code configuration
The Code configuration tab contains the decoding settings parameters for individual code
types. The code types are each assigned to a code structure.
As only activated code types are processed, the processing speed can be increased by
deactivating the code types that are not being used.
5.7.1 General
A wizard is available via the A
UTO button in the General group, which can be used to set the
code configuration automatically.
5.7.1.1 Automatic code configuration
Pressing the A
UTO button (Automatic code configuration) starts the auto-setup wizard for au-
tomatic code-type configuration.
To perform the code configuration automatically, a suitable code must be placed in the rea-
ding area.
5.7.2 1D Symbologies
The 1D Symbologies group contains all parameters for configuration of the 1D symbologies
(barcodes).
5.7.2.1 Minimum module width
The smallest structure for decoding a code is defined in mm via the Minimum module width
parameter.
To optimize the decoding process, the value should be adapted as closely as possible to the
smallest code element (module width) that actually exists within the code. An average mo-
dule width must be specified in order to read codes with varying module widths reliably.