Chapter 5 ONLINE HELP SOPAS
LECTOR®620
162 © SICK AG · Germany · All rights reserved · Subject to change without notice 8013778/Y269/2013-11-27
Parameters
5.10.13.6.5 Control
The Control parameter is used to choose between configuration with units of length or con-
figuration with units of time.
• T
RACK CONTROLLED: The entries for the Length parameter are made in mm.
• T
IME CONTROLLED: The entries for the Length parameter are made in ms.
5.10.13.6.6 Length
If the T
IMER/TRACKING condition is selected under the Function (Off) parameter, you can use
the Length parameter to enter the duration for which the digital output remains activated.
The unit can be selected in the Control parameter.
5.10.13.7 Beeper
The Beeper group contains the parameters for adjusting the acoustic signal.
As with the digital outputs, it is possible to select an event that activates the beeper. As soon
as this event occurs, it is fed back acoustically by the beeper.
5.10.13.7.1 Beeper
The Beeper parameter is used to select the event for which the beeper is activated.
• G
OOD READ: The beeper sounds if the reading was successful.
• N
O READ: The beeper sounds if the reading was unsuccessful.
• T
EACH-IN 1 OK: The beeper sounds if the MATCHCODE TEACH-IN 1 was taught in successfully.
• T
EACH-IN 1 NOK: The beeper sounds if the MATCHCODE TEACH-IN 1 was not taught in suc-
cessfully.
• T
EACH-IN 2 OK: The beeper sounds if the MATCHCODE TEACH-IN 2 was taught in successfully.
• T
EACH-IN 2 NOK: The beeper sounds if the MATCHCODE TEACH-IN 2 was not taught in suc-
cessfully.
• C
ONDITION MATCH 1 : The beeper sounds if the read code corresponds to the matchcode
from C
ONDITION MATCH 1.
• C
ONDITION MULTCODES1: The beeper sounds if the number of read codes corresponds to
the required number from C
ONDITION MULTCODES1.
• C
ONDITION TEACHIN1: The beeper sounds if the read code corresponds to the matchcode
from C
ONDITION TEACHIN1.
• C
ONDITION TEACHIN2: The beeper sounds if the read code corresponds to the matchcode
from C
ONDITION TEACHIN2.
5.10.13.7.2 Volume
The Volume parameter can be used to deactivate the beeper (O
FF) or set the volume of the
beeper (L
OUD or SOFT).
As a result, the beeper can be adapted to background noise.