ONLINE HELP SOPAS Chapter 5
LECTOR®620
Parameters
8013778/Y269/2013-11-27 © SICK AG · Germany · All rights reserved · Subject to change without notice 159
5.10.13.5.2 Function (Off)
The Function (Off) parameter is used to select the event for which the digital output is deac-
tivated.
• T
IMER/TRACKING: The output is deactivated after a certain period of time (Length).
• N
EXT OBJECT TRIGGER: The output is deactivated as soon as the next reading gate is opened.
• SOPAS C
OMMAND: The output is deactivated by a command. As a result, the defined sta-
tuses can be displayed via a connected control lamp as a result of a controller (PLC) com-
mand.
• G
OOD READ: The output is deactivated in the event of a successful reading.
• N
O READ: The output is deactivated in the event of an unsuccessful reading.
• T
EACH-IN 1 START: The output is deactivated as soon as the processing for teaching in the
M
ATCHCODE TEACH-IN 1 starts.
• T
EACH-IN 2 START: The output is deactivated as soon as the processing for teaching in the
M
ATCHCODE TEACH-IN 2 starts.
• C
ONDITION MATCH 1: The output is deactivated if the read code corresponds to the match-
code from C
ONDITION MATCH 1.
• C
ONDITION MULTCODES1: The output is deactivated if the number of read codes corre-
sponds to the required number from C
ONDITION MULTCODES1.
• C
ONDITION TEACHIN1: The output is deactivated if the read code corresponds to the match-
code from C
ONDITION TEACHIN1.
• C
ONDITION TEACHIN2: The output is deactivated if the read code corresponds to the match-
code from C
ONDITION TEACHIN2.
5.10.13.5.3 Or
You can use the Or parameter to choose a second condition for deactivating the digital out-
put.
One of the conditions must be met for the digital output to be deactivated.
• ---: Second condition not selected.
• C
ONDITION MATCH 1: The output is deactivated if the read code corresponds to the match-
code from C
ONDITION MATCH 1.
• C
ONDITION MULTCODES1: The output is deactivated if the number of read codes corre-
sponds to the required number from C
ONDITION MULTCODES1.
• C
ONDITION TEACHIN1: The output is deactivated if the read code corresponds to the match-
code from C
ONDITION TEACHIN1.
• C
ONDITION TEACHIN2: The output is deactivated if the read code corresponds to the match-
code from C
ONDITION TEACHIN2.
5.10.13.5.4 Logic
The Logic parameter is used to select the polarity of the digital output.
• N
OT INVERTED: On activation, the digital output switches from Low (0) to High (1).
• I
NVERTED: On activation, the digital output switches from High (1) to Low (0).