EasyManuals Logo

SICK Lector 620 Online Help

SICK Lector 620
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #66 background imageLoading...
Page #66 background image
Chapter 5 ONLINE HELP SOPAS
LECTOR®620
66 © SICK AG · Germany · All rights reserved · Subject to change without notice 8013778/Y269/2013-11-27
Parameters
5.7.12.1.3 DataBar Limited
If the DataBar Limited parameter is activated, decoding starts for the relevant code type.
As only activated code types are processed, you can increase the processing speed by
deactivating the code types that are not being used.
• Code name: GS1 DataBar Limited (GDBL)
• Character set: 14 fixed digits
• Structure: No quiet zone, the separator consists of a gap (1X) and a line (1X)
• Intrinsic safety: High
• Spatial requirements: Low
• Standard: ISO/IEC 24727
• Areas of application: Trade and industry (pharmaceuticals industry and electronics sec-
tor)
5.7.13 Pharmacode
If the Pharmacode parameter is activated, decoding is activated for the corresponding code
type. The configuration tab for the corresponding code type can be seen and opened in
SOPAS ET.
All other code types are deactivated.
• Code name: Pharmacode (binary)
• Character set: Numeric characters (integers between 3 and 131,070)
Structure: Wide bars: 1, narrow bars: 0 (main code and additional code can have different
colors)
• Intrinsic safety: High
• Spatial requirements: Low
• Standard: Laetus bar code standard
• Area of application: Packaging checks in the pharmaceutical industry (agreement with re-
ference code from a code list)
5.7.13.1 General
General (PHARMA)

Table of Contents

Other manuals for SICK Lector 620

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Lector 620 and is the answer not in the manual?

SICK Lector 620 Specifications

General IconGeneral
BrandSICK
ModelLector 620
CategoryCard Reader
LanguageEnglish