Chapter 9 Operating Instructions
M4000 Adv., Adv. A/P, Area
102 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8010797/YT72/2016-02-19
Subject to change without notice
Commissioning
Only M4000 Area 60/80:
Use a test rod that is not transparent to light and that has the following diameters:
60 mm for the M4000 Area 60
80 mm for the M4000 Area 80
Guide the test rod along the entire length of the area monitored:
immediately in front of the sender
in the middle between sender and receiver
immediately in front of the receiver
This must produce the following result:
On the receiver for the related multiple light beam safety device only the red LED is
allowed to illuminate and not the green or yellow LED
and
as long as the light beam is interrupted, it must not be possible to initiate the danger-
ous state.
Further tests
Check the protective device for damage or wear, particularly the mounting, the electrical
connection and the connection cable, the housing and the front screen.
Check whether the access to the hazardous area is only possible by interrupting the
light path between sender and receiver for the M4000 system (e.g. correct mounting of
mechanical protective devices).
Check whether the protective device is effective for the set operating mode.

Table of Contents

Other manuals for SICK M4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK M4000 Advanced and is the answer not in the manual?

SICK M4000 Advanced Specifications

General IconGeneral
TypeMultiple light beam safety device
Enclosure ratingIP65
Supply voltage24 V DC
Safety integrity levelSIL3
Performance levelPL e
Protection RatingIP65
Operating Voltage24 V DC
Number of beams2 to 4 beams
Resolution70 mm
Ambient operating temperature-25 °C ... +55 °C
Angular ResolutionNot applicable
Operating Temperature-25 °C ... +55 °C

Related product manuals