Electrical installation
8 Electrical installation
WARNING
Switch the power supply off!
The machine/system could inadvertently start up while you are connecting the devices.
Ensure that the entire machine/system is disconnected during the electrical installation.
Connect OSSD1 and OSSD2 separately!
You are not allowed to connect OSSD1 and OSSD2 together, otherwise signal safety will
not be ensured.
Connect OSSD1 and OSSD2 separately to the machine controller.
Ensure that the machine controller processes the two signals separately.
Prevent the formation of a potential difference between the load and the protective
device!
If you connect loads that are not reverse-polarity protected to the OSSDs or the safety
outputs, you must connect the 0 V connections of these loads and those of the corres-
ponding protective device individually and directly to the same 0 V terminal strip. This is
the only way to ensure that, in the event of a defect, there can be no potential diffe-
rence between the 0 V connections of the loads and those of the corresponding pro-
tective device.
1
2
1
2