EasyManuals Logo

SICK M4000 Advanced User Manual

SICK M4000 Advanced
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #123 background imageLoading...
Page #123 background image
Operating Instructions Chapter 13
M4000 Adv., Adv. A/P, Area
8010797/YT72/2016-02-19 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 123
Subject to change without notice
Technical specifications
M
4000 Passive (mirror deflection)
For
number of
beams
Beam separation S1
[mm]
Dimension L1
[mm]
Dimension L2
[mm]
2 500 635 664
M4000 Passive (fibre-optic deflection)
For
number of
beams
Beam separation S1
[mm]
Dimension L1
[mm]
Dimension L2
[mm]
2 500 635 664
4 300 1035 1064
If you use a two-beam M4000 Advanced A/P, then instead of the M4000 Passive you can
use one of the following alternatives:
two deflector mirrors PSK45 (see section 13.3.10 “Deflector mirror PSK45” on
page 129)
or
one mirror column (part number: 1041917, see section 14.5 “Deflector mirrors and
mirror columns” on page 138)
Tab.
47
:
Dimensions of the
M4000 Passive dependent
on the number of beams
Note

Table of Contents

Other manuals for SICK M4000 Advanced

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK M4000 Advanced and is the answer not in the manual?

SICK M4000 Advanced Specifications

General IconGeneral
TypeMultiple light beam safety device
Enclosure ratingIP65
Supply voltage24 V DC
Safety integrity levelSIL3
Performance levelPL e
Protection RatingIP65
Operating Voltage24 V DC
Number of beams2 to 4 beams
Resolution70 mm
Ambient operating temperature-25 °C ... +55 °C
Angular ResolutionNot applicable
Operating Temperature-25 °C ... +55 °C