OPERATION 7
79
Subject to change without notice
OPERATING INSTRUCTIONS | Master Data Analyzer
7.3.2 Measuring the volume
The volume measurement can be carried out as soon as a valid bar code or stable weight
value is available.
If the system is unable to detect a valid bar code (operating mode with bar code scanning)
or a stable weight (operating mode without bar code scanning), the volume measurement
is terminated and a corresponding error message appears.
You will receive a message saying that you require a valid bar code or stable weight
before you can proceed.
Recording the object dimensions
1. Hold the measurement gantry using the handles and slowly move it over the object.
The object’s contours will be recorded by both light grids.
Fig. 47: Moving the measurement gantry over the object
2. The circle symbol for the measurement status indicator still lights up yellow.
In the measurement window, a 2D display of the measured object appears on the right-
hand side during the measuring process.
3. You can stop and continue moving the measurement gantry, and thus the measurement
process, at any time. The recording of measurements will remain active as long as
some of the diodes are shadowed by the object.
Note

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK Master Data Analyzer and is the answer not in the manual?

SICK Master Data Analyzer Specifications

General IconGeneral
BrandSICK
ModelMaster Data Analyzer
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals