Repairs and modifications
DANGER
Im
proper work on the product
A modified product may not offer the expected protection if it is integrated incorrectly.
Apart from the procedures described in this document, do not repair, open, manip‐
ulate or otherwise modify the product.
2.2 Intended use
The safety laser scanner is an electro-sensitive protective device (ESPE) and is suitable
f
or the following applications:
Hazardous area protection
Hazardous point protection
Access protection
Mobile hazardous area protection (protection of automated guided vehicles)
The product may be used in safety functions.
The safety laser scanner must only be used within the limits of the prescribed and
specified technical data and operating conditions at all times.
Incorrect use, improper modification or manipulation of the safety laser scanner will
invalidate any warranty from SICK; in addition, any responsibility and liability of SICK for
damage and secondary damage caused by this is excluded.
2.3 Inappropriate use
The safety laser scanner works as an indirect protective measure and cannot provide
pr
otection from pieces thrown from the application nor from emitted radiation. Trans‐
parent objects are not detected.
The safety laser scanner is not suitable for the following applications, among others:
Outdoors
Underwater
In explosion-hazardous areas
2.4 Cybersecurity
Overview
T
o protect against cybersecurity threats, it is necessary to continuously monitor and
maintain a comprehensive cybersecurity concept. A suitable concept consists of organi‐
zational, technical, procedural, electronic, and physical levels of defense and considers
suitable measures for different types of risks. The measures implemented in this
product can only support protection against cybersecurity threats if the product is used
as part of such a concept.
You will find further information at www.sick.com/psirt, e.g.:
General information on cybersecurity
Contact option for reporting vulnerabilities
Information on known vulnerabilities (security advisories)
Communication interfaces
U
SB
Ethernet for EtherNet/IP CIP Safety, data output, configuration and diagnostics
Display and pushbuttons
SAFETY INFORMATION 2
8027909/2023-02-22 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™
11
Subject to change without notice

Table of Contents

Other manuals for SICK nanoScan3

Related product manuals