EasyManua.ls Logo

SICK nanoScan3 - Testing plan

SICK nanoScan3
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Available data:
•
St
atus of safety function
•
Status sleep mode
•
Contamination warning
•
Contamination error
•
Reference contour monitoring
•
Manipulation
•
Cut-off path (safety-oriented)
•
Cut-off path (Not safety-related)
•
Current monitoring case
•
Reset required
•
Application error
•
Device error
Assembly 113: output of the device, input of the control
•
CIP S
afety
•
Update cycle: 5 ms (or a multiple of this, depending on RPI)
•
Length: 16 bytes
Available data:
•
Status of safety function
•
Status sleep mode
•
Contamination warning
•
Contamination error
•
Reference contour monitoring
•
Manipulation
•
Cut-off path (safety-oriented)
•
Cut-off path (Not safety-related)
•
Current monitoring case
•
Reset required
•
Application error
•
Device error
Assembly 120: output of the device, input of the control (not safety-related)
•
CIP
•
U
pdate cycle: 5 ms (or a multiple of this, depending on RPI)
•
Length: 12 bytes
•
For automation and diagnostic tasks without safety implication
Available data:
•
Status of safety function
•
Status sleep mode
•
Contamination warning
•
Contamination error
•
Reference contour monitoring
•
Manipulation
•
Cut-off path (Not safety-related)
•
Reset required
•
Current monitoring case
•
Application error
•
Device error
4.6 Testing plan
The manufacturer of the machine and the operating entity must define all required
t
horough checks. The definition must be based on the application conditions and the
risk assessment and must be documented in a traceable manner.
4 PROJECT PLANNING
50
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™ 8027909/2023-02-22 | SICK
Subject to change without notice

Table of Contents