EasyManua.ls Logo

SICK nanoScan3

SICK nanoScan3
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Available data:
St
atus of safety function
Status sleep mode
Contamination warning
Contamination error
Reference contour monitoring
Manipulation
Cut-off path (safety-oriented)
Cut-off path (Not safety-related)
Current monitoring case
Reset required
Application error
Device error
Assembly 113: output of the device, input of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 16 bytes
Available data:
Status of safety function
Status sleep mode
Contamination warning
Contamination error
Reference contour monitoring
Manipulation
Cut-off path (safety-oriented)
Cut-off path (Not safety-related)
Current monitoring case
Reset required
Application error
Device error
Assembly 120: output of the device, input of the control (not safety-related)
CIP
U
pdate cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 12 bytes
For automation and diagnostic tasks without safety implication
Available data:
Status of safety function
Status sleep mode
Contamination warning
Contamination error
Reference contour monitoring
Manipulation
Cut-off path (Not safety-related)
Reset required
Current monitoring case
Application error
Device error
4.6 Testing plan
The manufacturer of the machine and the operating entity must define all required
t
horough checks. The definition must be based on the application conditions and the
risk assessment and must be documented in a traceable manner.
4 PROJECT PLANNING
50
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™ 8027909/2023-02-22 | SICK
Subject to change without notice

Table of Contents

Other manuals for SICK nanoScan3

Related product manuals