13 Technical data
13.1 Version numbers and functional scope
Functional scope
Older de
vices might not support the full functional scope of the latest Safety Designer.
To identify the different levels of the functionality, we use a three-digit version number.
The functional scope of the device is at the following locations:
•
Type label, Version field
•
Display, entry in the Hardware menu
•
Safety Designer, Overview dialog box (only with connected device)
•
Safety Designer, report
Table 29: Functional scope
Type code Version number Amendments and new func‐
t
ions
EtherNet/IP:
Minor Revi‐
sion
NANS3-CAAZ30IZ1 V 1.0.0
•
F
irst released version 1
Revision
T
o identify the different revision levels of the devices, we use a three-digit version
number. The revision level of the device is indicated on the type label in the Revision
field.
Table 30: Revision
Type code Version number Amendments and new functions
NANS3-CAAZ30IZ1 Rev 1.3.0
•
F
irst released version
13.2 Data sheet
Table 31: Features
nanoScan3 Pro – EtherNet/IP™
Protective field range ≤3.0m, details: see "Sensin
g range", page 121
Scanning range of the refer‐
ence contour field
Like protective field range, see "Sensing range", page 121
Scanning range of the con‐
tour detection field
Like protective field range, see "Sensing range", page 121
Warning field range ≤10m
Distance measurement range ≤40m
Fields ≤128
Simultaneously monitored
f
ields
≤8
Field sets ≤128
Monitoring case tables 4
Monitoring cases ≤128
Scanning angle 275° (–47.5° … 227.5°)
Protective field resolution 20mm, 30mm, 40mm, 50mm, 60mm, 70mm, 150mm,
200mm
Angular resolution 0.17°
Response time ≥85ms, details: see "R
esponse times", page 121
TECHNICAL DATA 13
8027909/2023-02-22 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™
117