9 Operation
9.1 Safety
NOTE
T
his document does not provide instructions for operating the machine in which the
safety laser scanner is integrated.
9.2 Regular thorough check
The thorough check is intended to ensure that the safety functions are fulfilling their
planned pur
pose and whether persons are being adequately protected.
►
Carry out the checks specified in the test plan of the manufacturer of the machine
and the operating entity.
9.3 Status indicators
1
LED ON status
2
LED OFF status
3
LED restart interlock/warning field
4
Display
5
Network LED LA1
6
Network LED NS
7
Network LED MS
8
Pushbutton
Table 24: Status LEDs
Number Function Color Meaning
1
ON state Green Lights up green when at least one
s
afety output is in the ON state.
2
OFF state Red Lights up red when at least one
s
afety output is in OFF state due to
an interrupted field.
Flashes red when a safety output is
in the OFF state due to an error.
OPERATION 9
8027909/2023-02-22 | SICK O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™
97
Subject to change without notice