7.21 Service
7.21.1 Restart device
If you have problems with the device, you can restart the device or subsections of the
de
vice (safety function, connections, additional functions).
Restarting safety function
T
he fastest type of restart
Serious errors remain, even if the cause has been rectified (for example a locking
state because of a supply voltage which is too low).
Communication with the device remains intact (connections for configuration,
safety function and data not relating to safety).
Communication beyond the device is not impaired.
Restarting safety function and connections
T
he device’s function is also re-established after serious errors if the cause has
been rectified.
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety). The device sets up communication
again automatically after restarting.
Communication beyond the device is not impaired.
Restarting device completely
T
he device behaves exactly as it does when the voltage supply is switched off and
back on again.
The device’s function is also re-established after serious errors if the cause has
been rectified.
Communication with the device is interrupted (connections for configuration,
safety function and data not relating to safety).
Communication beyond the device is interrupted. This may also affect devices
which communicate beyond the device.
7.21.2 EtherNet/IP
Overview
If t
he safety laser scanner has already been connected to a controller and should
be connected to another controller, the link to the old controller must be explicitly
removed.
Approach
1.
Click on Remove link to remove the link to the controller.
7.21.3 Factory settings
Overview
Be
fore reconfiguring the device, you can reset all settings to factory settings.
Resetting safety function to factory settings
T
he configuration for the safety function is reset to factory settings.
Communication beyond the device is not impaired.
7 C
ONFIGURATION
90
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™ 8027909/2023-02-22 | SICK
Subject to change without notice