Assembly 100: input of the device, output of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 8 bytes
Switching between monitoring cases via dual-channel information, like with devi‐
ces with locally-connected static control inputs.
Available data:
Start safety function
Monitoring case switching
Stop Event history
Activate sleep mode
Control input
Reset
Restarting safety function and connections
Restart device completely
Assembly 103: input of the device, output of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 16 bytes
Switching between monitoring cases via monitoring case number
Available data:
Start safety function
Stop Event history
Activate sleep mode
Monitoring case number
Reset
Restarting safety function and connections
Restart device completely
Assembly 105: input of the device, output of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 8 bytes
Switching between monitoring cases via dual-channel information, like with devi‐
ces with locally-connected static control inputs.
Monitoring case switching via safe speed information
Available data:
Start safety function
Monitoring case switching
Stop Event history
Activate sleep mode
Control input
Safe speed
Reset
Restarting safety function and connections
Restart device completely
Assembly 110: output of the device, input of the control
CIP S
afety
Update cycle: 5 ms (or a multiple of this, depending on RPI)
Length: 8 bytes
PROJECT PLANNING 4