Name Use Data type Definition Values Safety implica‐
t
ion
control input 2 (A2)
…
cont
rol input 16 (H2)
Safety function BOOL Control input 2 (A2) …
16 (H2)
State of the static con‐
trol input for monitoring
case switching.
0 = logic status
of the control
input is 0
Safety-relevant
parameter
1 = logic state of
t
he control input
is 1
ControlInputsValid Safety function BOOL State of the valid static
control inputs
0 = inputs invalid Safety-relevant
parameter
1 = inputs valid
CurrentMonitoringCaseNoTa‐
ble1
Diagnostics USINT Current monitoring
c
ase (Monitoring case
table 1)
Signals the current
(active) monitoring case
of monitoring case
table 1.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble2
Diagnostics USINT Current monitoring
c
ase (Monitoring case
table 2)
Signals the current
(active) monitoring case
of monitoring case
table 2.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of t
he current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble3
Diagnostics USINT Current monitoring
c
ase (Monitoring case
table 3)
Signals the current
(active) monitoring case
of monitoring case
table 3.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of t
he current
(active) monitor‐
ing case
CurrentMonitoringCaseNoTa‐
ble4
Diagnostics USINT Current monitoring
c
ase (Monitoring case
table 4)
Signals the current
(active) monitoring case
of monitoring case
table 4.
0 = no monitor‐
ing case is active
Parameter with‐
out safety impli‐
cation
1 … 254 = num‐
ber of the current
(active) monitor‐
ing case
DeviceError Diagnostics BOOL Device error
S
ignals whether a
device error (serious
error) is present, caus‐
ing the safety func‐
tion to be paused. To
resolve this, rectify the
cause of the error and
then restart the device.
0 = no device
error
Parameter with‐
out safety impli‐
cation
1 = device error
ManipulationStatus Diagnostics BOOL Manipulation
S
ignals if manipulation
has been detected
and the safety outputs
are therefore in the
OFF state, for example
because the device has
not detected an object
over a long period of
time.
0 = no manipula‐
tion detected
Parameter with
implication for
the safety func‐
tion
1 = manipulation
detected