EasyManuals Logo

Siemens Brodersen MC55 AT User Manual

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #133 background imageLoading...
Page #133 background image
MC55_ATC_V04.00 Page 133 of 475 3/17/06
Confidential / Released
7.6 ATD><str> Mobile originated call from active memory using cor-
responding field
Syntax
Command Description
This command searches the active phonebook for a given string <str> and dials the assigned phone number.
The termination character ";" is mandatory since dialing from a phonebook is only supported for voice calls and
for sending *# codes of Supplementary Services or other functions.
Parameter Description
String type value ("x"), which should equal an alphanumeric field in at least one phonebook entry in the searched
memories; used character set should be the one selected with AT+CSCS. <str> can contain escape sequences
as described in chapter "Supported character sets".
<str> must be wrapped in quotation marks (""), if escape sequences or parameter <mgsm> are used or if the
alphanumeric strings contains a blank. If not, quotation marks are optional.
If AT+CSCS is set to "UCS2", with respect to the coding of UCS2-characters only phonebook entries that contain
an alphanumeric string with as size less than the half of the parameter <tlength> from AT+CPBW can be
dialed.
String of GSM modifiers:
I Activates CLIR (disables presentation of own phone number to called party)
i Deactivates CLIR (enables presentation of own phone number to called party)
Notes
• This command may be aborted generally by receiving a character during execution. Abortion is not possible
during some states of connection setup such as handshaking.
• The command is not applicable to data calls. Any attempt to dial <str> without semicolon ";" causes the
result code "NO CARRIER" to appear.
• Parameter <mgsm> only if no *# code is within the dialing string.
Exec Command
ATD><str>[<mgsm>];
Response(s)
ERROR
+CME ERROR: <err>
If no dialtone (parameter ATX2 or ATX4):
NO DIALTONE
If busy (parameter setting ATX3 or ATX4):
BUSY
If connection cannot be set up:
NO CARRIER
When TA returns to command mode after call release:
OK
If successfully connected:
OK
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge  Last
V.250 % % § % § § ! ! !
<str>
(str)(+CSCS)
<mgsm>
(str)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Brodersen MC55 AT and is the answer not in the manual?

Siemens Brodersen MC55 AT Specifications

General IconGeneral
BrandSiemens
ModelBrodersen MC55 AT
CategoryModem
LanguageEnglish

Related product manuals