13.22 AT^SSCONF SMS Command Configuration
AT^SSCONF controls details of some SMS releated commands. Please note that AT^SSCONF settings are stored
volatile, i.e. after restart or reset the default values will be restored.
Syntax
Parameter Description
Display recipient address
[0]
(&F)
MC55 does not display <ra> and <tora>. These parameters are used with
the result codes of AT+CMGL, AT^SMGL, AT+CMGR, AT^SMGR and the URC
"+CDS".
1 MC55 displays <ra> and <tora>.
Test Command
AT^SSCONF=?
Response(s)
^SSCONF:list of supported <ra>s
OK
Read Command
AT^SSCONF?
Response(s)
^SSCONF:<ra>
OK
Write Command
AT^SSCONF=<ra>
Response(s)
OK
PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
! % % % % % ! ! !