EasyManua.ls Logo

Siemens Brodersen MC55 AT - AT&S Set Circuit Data Set Ready (DSR) Function Mode

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55_ATC_V04.00 Page 88 of 475 3/17/06
Confidential / Released
4.4 AT&S Set circuit Data Set Ready (DSR) function mode
The AT&S command determines how the TA sets circuit 107 (DSR) depending on the communication state of
the TA interfacing TE.
Syntax
Parameter Description
[0]
(&F)
DSR line is always ON
1 TA in command mode: DSR is OFF.
TA in data mode: DSR is ON.
Exec Command
AT&S[<value>]
Response(s)
OK
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
V.250 ! % ! % % % ! ! !
<value>
(num)(&W)(&V)

Table of Contents