7.14 ATS8 Set number of seconds to wait for comma dialing modifier
This command specifies the amount of time, in seconds, that the DCE shall pause, during signalling of call
addressing information to the network (dialling), when a "," (comma) dial modifier is encountered in a dial string.
Syntax
Command Description
No effect for GSM.
Parameter Description
0
(&F)
DCE does not pause when "," encountered in dial string
1...255 Number of seconds to pause
Read Command
ATS8?
Response(s)
<n>
OK
Write Command
ATS8=<n>
Response(s)
OK
ERROR
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
V.250 ! % ! % ! ! ! ! !
<n>
(num)(&W)(&V)

Table of Contents