EasyManua.ls Logo

Siemens Brodersen MC55 AT - AT+CMGC Send an SMS Command

Siemens Brodersen MC55 AT
475 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MC55_ATC_V04.00 Page 335 of 475 3/17/06
Confidential / Released
13.2 AT+CMGC Send an SMS command
Syntax
Notes
After invoking the commands AT+CMGW, AT+CMGS or AT+CMGC it is necessary to wait for the prompt ">"
before entering text or PDU. After the prompt a timer will be started to observe the input.
At baudrates below 19200 it is recommended to use the line termination character only (refer to ATS3, default
<CR>) before entering the text or PDU. Use of the line termination character followed by the response format-
ting character (refer to ATS4, default
<LF> can cause problems
Test Command
AT+CMGC=?
Response(s)
OK
Write Command
If text mode (see AT+CMGF=1)
AT+CMGC=<fo>, <ct>[, <pid>[, <mn>[, <da>[, <toda>]]]]
<CR> Text can be entered <CTRL-Z>/<ESC>
Response(s)
+CMGC: <mr>[, <scts>]
If sending fails
ERROR
+CMS ERROR
Write Command
If PDU mode (see AT+CMGF=0)
AT+CMGC=<length>
<CR> PDU can be entered <CTRL-Z>/<ESC>
Response(s)
+CMGC: <mr>[, <ackpdu>]
OK
If sending fails
ERROR
+CMS ERROR
Reference(s) PIN ASC0 ASC1 MUX1 MUX2 MUX3 Charge Last
GSM 07.05 % % % % % % ! ! !

Table of Contents