11.20 Using GPRS AT commands (Examples)
Examples
EXAMPLE 1
Defining and using a Context Definition ID (CID):
Every time a CID is used as a parameter for a GPRS command the CID has to be defined before by using
the AT+CGDCONT command. To get the parameter of a CID use the AT+CGDCONT read option. If the response
of 'AT+CGDCONT?' is OK only, there is no CID defined.
All parameters of the CID are initiated by NULL or not present values, and the CID itself is set to be undefined.
To define a CID use the AT+CGDCONT command with at least one CID parameter. At the moment the mobile
supports CID 1 and CID 2 by using the AT+CGDCONT command.
Define CID 1 and set the PDP type to IP, access point name and IP address are not set:
Define CID 2 and sets PDP type, APN and IP addr:
A following read command will respond:
Set the CID 1 to be undefined:
A following read command will respond:
AT+CGDCONT?
OK
There is no CID defined
AT+CGDCONT=1,"IP"
OK
AT+CGDCONT=2,"IP", "internet.t-d1.gprs", 111.222.123.234
OK
AT+CGDCONT?
+CGDCONT:1,"IP","","",0,0
+CGDCONT:2,"IP","internet.t-d1.gprs",111.222.123.234
OK
AT+CGDCONT=1
OK
AT+CGDCONT?
+CGDCONT:2,"IP","internet.t-d1.gprs",111.222.123.234
OK

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Brodersen MC55 AT and is the answer not in the manual?

Siemens Brodersen MC55 AT Specifications

General IconGeneral
BrandSiemens
ModelBrodersen MC55 AT
CategoryModem
LanguageEnglish

Related product manuals